Commit Graph

11 Commits

Author SHA1 Message Date
e0c7f20970 increased SYNC_DETector frequency up to 2.42 MHz. also now ADC clock freq is equal to Mach-Zander freq. Because ADC samples at both rising and falling edges 2026-02-02 17:04:00 +03:00
f92f6de5bf Now ADC clock freq is equal to Mach_Zander clock. ADC samples on rising and falling edges 2026-01-28 17:00:05 +03:00
a3c38516d3 implemented setting HIGH of OUT_6, OUT_7 at 1/3 and 2/3 of laser current change cycle. Both are reseted at the end of cycle. their purpose -- switch amplifier stages of signal after detector, before ADC. NOT TESTED! 2025-11-21 14:20:07 +03:00
f2004bdc35 Now PG9 toggles at the very beginning of every laser current step. Purpose: tell ADC that step started/ended for correct averaging. 2025-10-22 12:00:48 +03:00
03bb95db58 modified ADC trigger: now it starts before ADC samplig (as it was), stops after some ADC clocks (while in current varying routine) 2025-10-16 17:33:05 +03:00
76b6bb36f8 added build folder. Now compilde binary becomes available in git 2025-09-18 16:54:16 +03:00
ca8405bb41 removed build folder from git index 2025-03-04 12:17:54 +03:00
b02e3a35b7 solved laser current setup timing issue 2025-03-04 11:43:09 +03:00
59dce26129 applied last changes from version without git 2025-03-03 16:06:13 +03:00
d0637bb5e6 switched project to make 2025-03-03 16:03:02 +03:00
2d2912a771 initial software commit 2025-03-03 15:53:11 +03:00