e0c7f20970
|
increased SYNC_DETector frequency up to 2.42 MHz. also now ADC clock freq is equal to Mach-Zander freq. Because ADC samples at both rising and falling edges
|
2026-02-02 17:04:00 +03:00 |
|
|
|
f92f6de5bf
|
Now ADC clock freq is equal to Mach_Zander clock. ADC samples on rising and falling edges
|
2026-01-28 17:00:05 +03:00 |
|
|
|
a3c38516d3
|
implemented setting HIGH of OUT_6, OUT_7 at 1/3 and 2/3 of laser current change cycle. Both are reseted at the end of cycle. their purpose -- switch amplifier stages of signal after detector, before ADC. NOT TESTED!
|
2025-11-21 14:20:07 +03:00 |
|
|
|
f2004bdc35
|
Now PG9 toggles at the very beginning of every laser current step. Purpose: tell ADC that step started/ended for correct averaging.
|
2025-10-22 12:00:48 +03:00 |
|
|
|
03bb95db58
|
modified ADC trigger: now it starts before ADC samplig (as it was), stops after some ADC clocks (while in current varying routine)
|
2025-10-16 17:33:05 +03:00 |
|
|
|
76b6bb36f8
|
added build folder. Now compilde binary becomes available in git
|
2025-09-18 16:54:16 +03:00 |
|
|
|
ca8405bb41
|
removed build folder from git index
|
2025-03-04 12:17:54 +03:00 |
|
|
|
b02e3a35b7
|
solved laser current setup timing issue
|
2025-03-04 11:43:09 +03:00 |
|
|
|
59dce26129
|
applied last changes from version without git
|
2025-03-03 16:06:13 +03:00 |
|
|
|
d0637bb5e6
|
switched project to make
|
2025-03-03 16:03:02 +03:00 |
|
|
|
2d2912a771
|
initial software commit
|
2025-03-03 15:53:11 +03:00 |
|